Back to top
08045813594
Send SMS    Call Me Free Send Inquiry
200KVA Distribution Transformer
200KVA Distribution Transformer
200KVA Distribution Transformer
200KVA Distribution Transformer
200KVA Distribution Transformer
200KVA Distribution Transformer

200KVA Distribution Transformer

MOQ : 1 Unit

200KVA Distribution Transformer Specification

  • High Voltage
  • 11kV Volt (V)
  • Dimension (L*W*H)
  • 1470 x 900 x 1670 mm Millimeter (mm)
  • Coil Material
  • Copper
  • Voltage Booster Type
  • Other
  • Load Loss
  • 1700W (at 75C)
  • Rated Voltage
  • 11kV/433V Volt (V)
  • Cooling Type
  • Oil Cooled
  • Standard
  • IS-1180
  • Low Voltage
  • 433V Volt (V)
  • Operating Temperature
  • -25C to +45C Celsius (oC)
  • Power Rating
  • 200kVA
  • Product Type
  • Distribution Transformer
  • Material
  • Copper
  • Output
  • 433V
  • Frequency (MHz)
  • 50 Hz Hertz (HZ)
  • Efficiency
  • Level II
  • Phase
  • Three Phase
  • Usage
  • Distribution
  • Coil Structure
  • Double Wound
  • Coil Number
  • 2
  • Power Scope
  • 200kVA
  • Weight
  • Approx. 1100 kg Kilograms (kg)
  • Core Type
  • CRGO/Laminated
  • Tank Type
  • Hermetically sealed
  • Bushings
  • Porcelain, Oil Filled
  • Protection
  • Pressure relief valve
  • Color
  • Industrial Grey
  • Mounting Type
  • Pole Mounted
  • Tap Changer
  • Off-circuit
  • Insulation Class
  • Class A
 

200KVA Distribution Transformer Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About 200KVA Distribution Transformer



Introducing our elite 200KVA Distribution Transformer, designed for superb performance and sterling reliability. This highly recommended, affordable unit is engineered for pole mounting and features professional-grade Class A insulation and a hermetically sealed tank. It incorporates CRGO-laminated core, double-wound copper coils, porcelain bushings, and off-circuit tap changer for versatile distribution needs. The polished, industrial grey finish complements pristine build quality, while efficiency Level II ensures consistent power delivery. Certified to IS-1180 standards, this oil-filled, three-phase transformer promises robust protection with a pressure relief valve and is perfect for a multitude of power distribution environments.

Versatile Application Across Distribution Networks

The 200KVA Distribution Transformer is perfectly suited for general and specific distribution requirements, delivering stable power in residential, commercial, and industrial sectors. Engineered for pole mounting, its surface of application spans utility lines and localized grids where reliability and space efficiency are critical. With a conventional voltage booster, this transformer excels in supply networks demanding consistent performance and long-term durability for streamlined, uninterrupted power supply.


Dependable Supply and Hassle-Free Shipping

Primarily serving the Indian domestic market, our 200KVA Distribution Transformer is supplied with superb consistency and reliability. With rapid supply ability, customers across the country benefit from prompt shipment. Our export-ready units are shipped securely with full freight management. Samples are available upon request, ensuring potential buyers can inspect quality and performance before full-scale deployment. Experience seamless shipment, proper handling, and dedicated after-sales support with every order.


FAQ's of 200KVA Distribution Transformer:


Q: How is the 200KVA Distribution Transformer best utilized?

A: The 200KVA Distribution Transformer is designed for use in electrical distribution networks, especially for pole-mounted installations in commercial, industrial, and residential areas. It provides stable voltage transformation from high voltage (11kV) to low voltage (433V) distribution.

Q: What are the benefits of a hermetically sealed and oil-filled tank?

A: The hermetically sealed, oil-filled tank prevents moisture ingress, enhancing reliability and lifespan. The oil offers superior insulation and cooling, ensuring optimal operation and safeguarding internal components under demanding conditions.

Q: Where can this transformer be installed?

A: This unit is specifically designed for pole mounting, making it suitable for outdoor applications in utility grids, distribution substations, and other power delivery points requiring elevated installations.

Q: What is the process for ordering and receiving a sample?

A: Interested buyers can request a sample through our sales team. Once requested, the sample transformer will be shipped promptly with all necessary freight and shipment arrangements handled by our logistics team.

Q: How does the transformer ensure efficient power distribution?

A: With an efficiency Level II rating, CRGO-laminated core, double-wound copper coils, and robust protection features like a pressure relief valve, the transformer ensures minimal load loss (1700W at 75C) and consistent voltage regulation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Distribution Transformers Category

160KVA Distribution Transformers

160KVA Distribution Transformers

Minimum Order Quantity : 1 Unit

Cooling Type : Oil Cooled

Rated Voltage : 11kV/433V

Coil Material : Other , Copper

Voltage Booster Type : Other, Conventional

Load Loss : Approx. 1250W

1250KVA Distribution Transformer

1250KVA Distribution Transformer

Minimum Order Quantity : 1 Unit

Cooling Type : Oil Cooled

Rated Voltage : 11 kV / 433 V

Coil Material : Other , Copper

Voltage Booster Type : Other, OnLoad Tap Changer (optional)

Load Loss : As per IS1180 Std.

250KVA OLTC Distribution Transformers

250KVA OLTC Distribution Transformers

Minimum Order Quantity : 1 Unit

Cooling Type : ONAN

Rated Voltage : 11kV/433V

Coil Material : Other , Copper

Voltage Booster Type : Other, OLTC (On Load Tap Changer)

Load Loss : 2100 W (at full load)

400KVA Distribution Transformer

400KVA Distribution Transformer

Minimum Order Quantity : 1 Unit

Cooling Type : Oil Cooled

Rated Voltage : 11 kV / 415 V

Coil Material : Other , Copper

Voltage Booster Type : Other, OffCircuit Tap Changer (OCTC)

Load Loss : Max 4800 W